Nortel Meridian 1 Manual page 134

System installation procedures
Table of Contents

Advertisement

Page 96 of 500
Configuring the system monitor
Figure 53
Options 71, 81, and 81C—cabling for master system monitor to slave unit 1 and SDI port
To SDI port
NT8D46AD
Backplane
CPU 0
power supply assembly
553-3001-210 Standard 14.00 June 1999
For options 71, 81, and 81C
Connect the master system monitor to slave unit 1 with an
NT8D46AS cable.
Connect the narrow ribbon on an NT8D46AD cable from connector
J2 in the module with CPU 0 to the assigned port on the SDI card
(see Figure 53).
To next module
cable
To system monitor/
in the pedestal
J2
J1
Backplane
CPU 1
NT8D46AS cable
To next module
NT8D46AA
cable
To system monitor/
power supply assembly
in the pedestal
553-3112
J2
J1
553-3112