Nortel Meridian 1 Manual page 370

System installation procedures
Table of Contents

Advertisement

Page 332 of 500
Figure 123
Card slots in the NT8D47 RPE Module
RPE Module
CE/PE Pwr Sup
Note: At the remote site, the QPC63 Local Carrier Buffer Cards are replaced by
the QPC65 Remote Peripheral Switch Cards.
553-3001-210 Standard 14.00 June 1999
Configuring remote peripheral equipment
Loop A
1
2
3
4
DTI
1.5 Mb Conv 2Mb Conv
Carr Int
In an RPE configuration, the common equipment site is the "local" site; the
site without common equipment is the "remote" site.
If the distance between local and remote sites is more than 726 m (2500 ft),
an office repeater bay (ORB) is required to effectively isolate the carrier span
from the Meridian 1 equipment (see Figure 124). An ORB provides:
— span line powering
— error monitoring
— fault-locate system access
— order-wire termination with DID access
— line looping
RPE
Loop B
5
6
7
8
9
2Mb Conv 1.5 Mb Conv C arr Maint
Lcl Rem Bfr
Lcl Rem Bfr Carr Int
10
11
12
DTI
DTI
Remote Peripheral Equipment
Loop
553-5313
553-5313