Figure; Table - Nortel Meridian 1 Manual

System installation procedures
Table of Contents

Advertisement

Page 468 of 500
553-3001-210 Standard 14.00 June 1999
Appendix C: Backplane cabling in NT8D11 and NT8D37 modules
NT8D37 backplane cable expansion: Segment 3
1
Leave cable R as is in slot position L12.
2
Move cable end S-3 to slot position L13-3.
3
Remove cable T from the backplane and connect cable ends T-1, T-2,
and T-3 to slot positions L14-1, L14-2, and L14-3.
4
Add cable U to the I/O panel by connecting cable ends U-1, U-2, and U-3
to slot positions L15-1, L15-2, and L15-3.
Table 139 lists cable connections for a fully expanded configuration.
Figure 172 shows the backplane slots in a fully expanded configuration.

Table 139

NT8D37 cable connections: expanded configuration
Backplane slots-shroud rows
L0-1, 2, 3
L1-1, 2, 3
L2-1, 2, 3
L3-1, 2, 3
L4-1, 2, 3
L5-1, 2, 3
L6-1, 2, 3
L7-1, 2, 3
L8-1, 2, 3
L9-1, 2, 3
L10-1, 2, 3
L11-1, 2, 3
L12-1, 2, 3
L13-1, 2, 3
L14-1, 2, 3
L15-1, 2, 3
I/O panel/cable designation
A
B
C
D (new cable)
E
F
G
H (new cable)
K
L
M
N (new cable)
R
S
T
U (new cable)

Advertisement