Nortel Meridian 1 Manual page 178

System installation procedures
Table of Contents

Advertisement

Page 140 of 500
Figure 71
NT5D21 Core/Net Module (rear)—connections for IOP/CMDU to IOP/CMDU and CP to CP
cables
Core/Net Module 0
18 17 16 15 14 13 12 11 10 9 8
553-3001-210 Standard 14.00 June 1999
Cabling common equipment
Connect the NTND13 IOP to IOP SCSI Cable from backplane
connector position 17A in Core/Net 0 to backplane connector
position 17A in Core/Net 1 (see Figure 71).
Connect one NTND11 CP to CP Cable from backplane connector
position 15C in Core/Net 0 to backplane connector position 15C in
Core/Net 1 (see Figure 71).
Connect another NTND11 cable from backplane connector position
15A in Core/Net 0 to backplane connector position 15A in
Core/Net 1 (see Figure 71).
Reinstall the left I/O panels in both Core/Net Modules. Use and
tighten all eight screws.
A
B
C
D
E
F
NTND13 cable: 17A to 17A
NTND11 cables: 15C to 15C, 15A to 15A
Core/Net Module 1
18 17 16 15 14 13 12 11 10 9 8
A
B
C
D
E
F
553-6398
553-6398

Advertisement

Table of Contents
loading

Table of Contents