Connecting trunks without PFTU

Connecting trunks with PFTU

Procedure 62
Connecting trunks without PFTU
1
From the assignment record, determine the location of the trunk
connection and its associated Terminal Number (TN) at the
cross-connect terminal.
2
With cross-connect wire, connect the trunk to the TN.
Make sure that the wiring is not reversed and is on the correct terminals.
Tables 51 to 53 list the connections for trunks. For trunk connections for
Europe, see Tables 54 to 62. For trunk connections for the UK, see
Tables 63 to 69.
Procedure 63
Connecting trunks with PFTU
1
Locate the PFTU terminal blocks at the cross-connect terminal.
2
Cross-connect the first pair of the assigned PFT to the telephone.
Refer to Table 50 on
3
Cross-connect the second pair of the PFT to the TN assigned to the
telephone.
4
Cross-connect the third pair of the PFT to the Central Office trunk.
5
Cross-connect the third pair of the PFT to the TN assigned to the trunk.
6
Repeat for each trunk assigned to the PFTU.
Connecting the trunks
End of Procedure
page 362
for PFTU connections.
End of Procedure
Small System
Page 361 of 562
Installation and Configuration