60

CoolSmart TV - Installation Requirements

Upper Manifold Framing
Ceiling
Min. 1-1/2" (39mm)
3-3/4"
(96mm)
Max. 3-1/8"
Max. 120"
(80mm)
(3048mm)
Min. 67-1/4"
(1709mm)
Grill and Manifold Dimensions
The grill may be installed over the
facing to provide an aesthetic
opening for the convection outlet. (2)
8-32 x 1-1/2" screws attach the trim to
the upper manifold. This allows
variable thickness of finish material.
Dimensions
a
42" (1067mm)
© Travis Industries
Optional Equipment
1-1/4" (32mm)
1-3/4" (45mm)
3/4" (20mm)
Manifold
Manifold Support Bracket
Lower Manifold Framing
Min. 1" (26mm) Clearance from
Flex Duct to Combustibles
Factory installed
Metal Fireplace Header
5" (127mm) Alum. Flex Duct (included)
b
2-7/8" (74mm)
1-1/4" (32mm)
4/23/2021 - 1353
3/8" (10mm)
Max. 3-1/8" (80mm)
*This area may be supported using
1" strips of non-combustible material
spaced a minimum of 12" (305mm)
c
d
41" (1042mm)
Min. 1-1/4" (32mm)
Clearance from Top, Sides
and Back to Combustibles
Min. 3-1/2" (89mm)
Max. 1-1/2" (39mm)
Min. 1/2" (13mm) *
e
1-3/4" (45mm)
4415HO GSR2