Facing Example – Standard Position - Tile-Over Finish
Install cement board (or other non-combustible) from the base of the fireplace to the top of the
horizontal support (37-3/8" above the base) and to the framing opening on both sides (see "a" below).
Drywall (or other combustible) may be placed above the horizontal support (37-3/8" above the base of
the fireplace - see "b" below) and to the sides of the framing opening (see "b" below).
Tile or other non-combustible facing may be placed along the front of the fireplace around the perimeter
of the glass opening (see "c" below). Typical installations use 12" (305mm) or greater of non-
combustible facing around the perimeter of the glass opening. Do not install facing over the ledge to
the glass opening.
HINT:
We recommend the use of a trim kit for a tile over installation. The trim helps conceal the
area between the non-combustible facing and the glass opening.
WARNING: Do not place drywall or other combustibles over the front of the fireplace.
© Travis Industries
Installation
(for qualified installers only)
4/23/2021 - 1353
39