Vent Configuration: Horizontal Termination with Vertical Rise – 8" Vent
 Use 5x8" Diameter Coaxial Vent
 NOTE: Use the included firestop (s). The included heat shield may be discarded.
 The termination must fall within the shaded area shown in the chart. Use the indicated
restrictor positions.
 Up to 3 elbows (30°, 45°, 60° or 90°) may be used. Only one horizontal elbow may be used.
 HINT: Use minimum vent kit "H" (96200332) from Travis Industries (additional vent may be
required).
This is considered a
horizontal elbow (it doesn't
matter whether it turns right
or left). It may be a 30°, 45°,
60°, or 90° elbow.
© Travis Industries
Installation
(for qualified installers only)
H2
Horizontal length is calculated by
adding both lengths of horizontal run
(Horizontal Length = H1 + H2).
H1
4/23/2021 - 1353
This is
considered a
vertical elbow.
4415HO GSR2