FireplaceXtrordinair 98501001 Installation And Owner's Manual

Fireplacextrordinair electric fireplace insert 38"-40"-42" wide

Advertisement

Quick Links

ELECTRIC FIREPLACE INSERT

INSTALLATION AND OWNER'S MANUAL
Small Fireplace Insert (38" Wide) 98501001
Medium Fireplace Insert (40" Wide) 98501002
Large Fireplace Insert (42" Wide) 98501003
Read these instructions completely before beginning installation. Failure to follow them could
cause a heater
malfunction and result in serious injury and/or property damage.
WARNING: All electric heaters have hot or sparking parts inside. Do not use it in areas where
gasoline, paint or flammable liquids are stored.
WARNING: This heater is tested and listed for use only with the optional accessories listed in
these instructions. Use of optional accessories not specifically tested for this heater could void
the heater warranty
and/or result in a safety hazard.
1

Advertisement

Table of Contents
loading

Summary of Contents for FireplaceXtrordinair 98501001

  • Page 1: Electric Fireplace Insert

    ELECTRIC FIREPLACE INSERT INSTALLATION AND OWNER’S MANUAL Small Fireplace Insert (38” Wide) 98501001 Medium Fireplace Insert (40” Wide) 98501002 Large Fireplace Insert (42” Wide) 98501003 Read these instructions completely before beginning installation. Failure to follow them could cause a heater malfunction and result in serious injury and/or property damage.
  • Page 2: Safety Information

    Keep this manual for future reference. SAFETY INFORMATION Due to high temperatures, the insert should be located out of traffic and away from furniture and draperies. Do not place clothing or other flammable material on or near the insert. Never place any objects on the insert. The insert can become very hot when running.
  • Page 3: Listing Approvals

    12. Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons. 13. Avoid the use of an extension cord because the extension cord may overheat and cause a fire. If you have to use an extension cord, the cord should be No.
  • Page 4 Small Fireplace Insert (38” Wide) 98501001 8 3/4" [221mm] 24 1/4" [613mm] 38" [965mm] 9 3/4" [246.8mm] 25 1/4" [641.6mm] Medium Fireplace Insert (40” Wide) 98501002 8 3/4" [221mm] 26 3/4" [682mm] 40" [1015mm] 9 3/4" [247mm] 29 1/2" [747mm]...
  • Page 5 Large Fireplace Insert (42” Wide) 98501003 8 3/4" [221mm] 30" [762mm] 42" [1066.8mm] 9 3/4" [246.8mm] 31 3/4" [806.6mm]...
  • Page 6: Locating The Fireplace Insert

    LOCATING THE FIREPLACE INSERT WARNING: Never locate this heater where it may fall into a bathtub or any water container. NOTICE: All clearances must be maintained to combustibles. Illustrations throughout these instructions reflect typical installations and are for design purposes only. Actual installations may vary slightly due to individual preferences.
  • Page 7: Clearances When Built-In

    CLEARANCES WHEN BUILT-IN MANTEL(maximum 12" (305mm) deep WALL MINIMUM 3/8" (10mm) CLEARANCE TO TOP 2"[50.8 mm] OF APPLIANCE( combustible or non-combustible) FRONT GLASS APPLIANCE SIDE VIEW MINIMUM 1" (25.4mm) CLEARANCE TO SIDES AND BACK OF APPLIANCE (combustible or non-combustible) FLOOR The fireplace insert may be placed within a framed enclosure that is level, dry, and capable of supporting the weight of the appliance and front glass.
  • Page 8: Installation

    INSTALLATION CAUTION: The unit's power supply cord must be connected to a properly grounded and protected 120-volt outlet. Always use ground fault protection where required by the electrical code. WARNING - RISK OF FIRE! To prevent a possible fire, do not block the grills, louvers, or air openings on the fireplace insert in any manner.
  • Page 9: Installation Overview - Masonry Fireplaces

    INSTALLATION OVERVIEW – MASONRY FIREPLACES Cover plate is required if chimney does not have suitable rain cap. 2” (50mm) Minimum HINT: Close and seal the damper to prevent air infiltration. Attach the "This fireplace has been altered..." plate to the fireplace (use two screws or other suitable method).
  • Page 10: Installation Overview - Zero-Clearance (Metal) Fireplaces

    INSTALLATION OVERVIEW – ZERO-CLEARANCE (METAL) FIREPLACES Cover plate is required if chimney does not have suitable rain cap. The log shelf, screen, and doors (if present) must be removed. 2” (50mm) Minimum HINT: Close and seal the damper to prevent air infiltration. HINT: Attach the "This fireplace has been Paint the interior of the...
  • Page 11 OPTIONAL DECORATIVE INTERIORS This insert is shipped with an under-lit log pre-installed. Glowing embers are also included with the fireplace insert if you want a different appearance. Glowing Embers Orange Platinum Mixed Removing The Log The under-lit log is shipped in place. On newer units, the log has tabs on each side that hold it in place. Remove the black interior side panel (or carefully remove the tabs) to remove the log set.
  • Page 12: Remote Control Operation

    OPERATING INSTRUCTIONS REMOVING THE SURROUND GLASS Before removing the surround glass, make sure to have a suitable location to place the surround glass once it is removed. Do not place the glass on sharp or uneven areas that may chip or damage the tempered glass. Use both hands to lift the surround glass directly up.
  • Page 13 REMOTE CONTROL OPERATION (continued) Note The remote control requires 2 AA batteries (not included). Note: The heater may release a slight odor the first time it is turned on. This is normal. The heating elements inside the heater will burn off any accumulated oils or dust during initial heating. This may also occur when dust accumulates on the heating elements over periods of non-use.
  • Page 14 REMOTE CONTROL OPERATION (continued) ON/OFF 5. Heater " " button: Press this button to turn the heater ON. The heater will always start at high heat setting 1500W. To turn the heater off press this button again. HIGH button: Press the high button to switch the heater to high heat setting 1500W. LOW button: Press the low button to switch the heater to LOW heat setting 750W.
  • Page 15: Direct Operation

    DIRECT OPERATION 1. Power ON/OFF switch 2. Heat control button 3. Flame control button 4. HEATER LED 5. POWER LED Plug the heater into a suitable outlet. 1) “Power ON/OFF” Set this switch to position I to turn the product ON. Setting it to O to turn the product OFF. The POWER LED will be lit when the fireplace insert is on.
  • Page 16: Cleaning And Maintenance

    CLEANING AND MAINTENANCE WARNING: Always disconnect the power and allow the heater to cool before performing any cleaning, maintenance or relocation. Turn the controls to OFF and remove the plug from the outlet or turn off the circuit breaker before attempting any cleaning. FRONT GLASS 1.
  • Page 17: Replacement Parts

    REPLACEMENT PARTS REF NO PART NO. DESCRIPTION REMARK 250-02868 HEATER ASSEMBLY 250-02869 CIRCULT BOART 250-02870 REMOTE RECEIVER 250-02871 3W LED ASSEMBLY 250-02872 LED STRIP FOR FLAME 250-02873 LED STRIP FOR FLAME 250-02874 LED STRIP FOR LOG 250-02875 LED STRIP FOR LOG 250-02876 LED STRIP FOR EMBER 250-02877...
  • Page 18: Troubleshooting

    TROUBLE SHOOTING WARNING: Always disconnect power and allow the heater to cool before performing any cleaning, maintenance or relocation. Turn the controls to OFF and remove the plug from the outlet or turn off the circuit breaker before attempting any cleaning. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY...
  • Page 19: Year Limited Warranty

    1 YEAR LIMITED WARRANTY Register your TRAVIS INDUSTRIES, INC. Limited 1 Year Warranty online at traviswarranty.com. TRAVIS INDUSTRIES, INC. warrants this electric appliance (appliance is defined as the equipment manufactured by TRAVIS INDUSTRIES,INC.) to be defect-free in material and workmanship to the original purchaser from the date of purchase as follows: Check with your dealer in advance for any costs to you when arranging a warranty call.

This manual is also suitable for:

9850100398501002

Table of Contents