Installation Requirements For Cold Environments - FireplaceXtrordinair Xtrordinair 44 Elite Installation Manual

Wood-burning zero-clearance fireplace
Hide thumbs Also See for Xtrordinair 44 Elite:
Table of Contents

Advertisement

8

Installation Requirements for Cold Environments

If you live in the area depicted in black (see Figure 4),
you must Install a cooling air "P" trap as detailed below
and install the blower on an internal wall. In addition,
make sure the homeowner follows the requirements
shown below to help minimize cold air being pulled into
the fireplace when it is not in use.
Install the Blower in an Internal Location
In cold environments the blower must be positioned
on an internal wall (see Figure 5). This eliminates
any chance of any outside air being drawn into the
convection chamber from the blower location.
NOTE: Do not place the blower inside a garage or
other area that may circulate fumes.
© Travis Industries
Installation
(for qualified installers only)