Vent Configuration: Vertical Termination

 Use 4x6-5/8" Diameter Coaxial Vent. Connect a 8" to 6-5/8" reducer directly to the
fireplace (sku 98900165).
 NOTE: The included pipe shield is not required and may be discarded. The included
firestops may be discarded.
 The termination must fall within the shaded area shown in the chart. Use the indicated
restrictor positions.
 Up to five elbows (30°, 45°, 60° or 90°) may be used. Only one horizontal elbow may be
used.
This is considered a
horizontal elbow (it doesn't
matter whether it turns right
or left). It may be a 30°, 45°,
60°, or 90° elbow.
© Travis Industries
Installation
(for qualified installers only)
H2
Horizontal length is calculated by
adding both lengths of horizontal run
(Horizontal Length = H1 + H2).
H1
4/23/2021 - 1353
This is
considered a
vertical elbow.