Vent Configuration: Horizontal Termination with Vertical Rise
Use 4x6-5/8" Diameter Coaxial Vent. Connect a 8" to 6-5/8" reducer directly to the
fireplace (sku 98900165).
NOTE: The included pipe shield is not required and may be discarded. The included
firestops may be discarded.
The termination must fall within the shaded area shown in the chart. Use the indicated
restrictor positions.
Up to 3 elbows (30°, 45°, 60° or 90°) may be used. Only one horizontal elbow may be used.
This is considered a
horizontal elbow (it doesn't
matter whether it turns right
or left). It may be a 30°, 45°,
60°, or 90° elbow.
© Travis Industries
Installation
(for qualified installers only)
H2
H1
4/23/2021 - 1353
Horizontal length is calculated by
adding both lengths of horizontal run
(Horizontal Length = H1 + H2).
This is
considered a
vertical elbow.
29
4415HO GSR2