Coolsmart Tv - Installation Requirements - FireplaceXtrordinair ProBuilder 54 Installation Manual

Table of Contents

Advertisement

CoolSmart TV - Installation Requirements

Upper Manifold Framing
Ceiling
Min. 1-1/2" (39mm)
3-3/4"
(96mm)
Max. 4-1/4"
Max. 120"
(3048mm)
Min. 66-1/2"
(1690mm)
Grill and Manifold Dimensions
The grill may be installed over the facing to
provide an aesthetic opening for the
convection outlet. (2) 8-32 x 1-1/2" screws
attach the trim to the upper manifold. This
allows variable thickness of finish material.
Dimensions
PB 42
42" (1067mm)
PB 54
57" (1448mm)
© Travis Industries
Installation
(for qualified installers only)
1-1/4" (32mm)
1-3/4" (45mm)
3/4" (20mm)
Manifold
Lower Manifold Framing
Min. 1" (26mm) Clearance from
Flex Duct to Combustibles
(108mm)
Fireplace Header
ProBuilder
Linear
Fireplace
a
b
2-7/8" (74mm)
2-7/8" (74mm)
3/8" (10mm)
Manifold Support Bracket
5" (127mm) Alum. Flex Duct (included)
* This area may be supported using
1" (26mm) strips of non-combustible
material spaced a minimum of 12"
(305mm).
b
e
a
c
c
1-1/4" (32mm)
1-1/4" (32mm)
4/19/23 - 1453
PB 42 & 54 MV/GSB2/GSR2 Install
Min. 1-1/4" (32mm)
Clearance from Top, Sides
and Back to Combustibles
Min. 3-1/2"
(89mm)
Max. 1-1/2" (39mm)
Max. 4-1/4" (108mm)
Min. 1/2" (13mm)*
Min. 3-1/2"
(89mm)
Max. 3"
(77mm)
d
d
41" (1042mm)
1-3/4" (45mm)
56" (1423mm)
1-3/4" (45mm)
75
e

Advertisement

Table of Contents
loading

This manual is also suitable for:

Probuilder 42

Table of Contents