Coolsmart Tv - Combustible "Over-Facing" (Optional) - FireplaceXtrordinair 4415 HO GSR2 Installation Manual

Hide thumbs Also See for 4415 HO GSR2:
Table of Contents

Advertisement

CoolSmart TV - Combustible "Over-Facing" (Optional)

When using the CoolSmart TV kit, Combustible material can be installed over the non-combustible board on the
front of the fireplace. To be clear, there will be (2) layers of board over the front of the appliance, one non-
combustible that covers the entire front of the fireplace, and a second layer that can be combustible material
that is placed on top of the non-combustible board.
The combustible material MUST be installed OVER 1/2" of non-combustible board.
WARNING: If using a trim kit, there is a ½ " air space required from the edge of the Tile Stop on the
fireplace. If no trim is being used, the airspace is not required (see below for details).
NOTE: Trim kits accommodate facing between ½" and 1" in depth.
Over Facing
Over Facing
© Travis Industries
Optional Equipment
WARNING
WITH
Trim Kit
Combustible Facing
Allowed
OVER
Non-Combustible board
Non-Combustible
Facing Only
Fireplace side
Trim Kit
WITH OUT
Trim Kit
Combustible Facing
Allowed
OVER
Non-Combustible board
Non-Combustible
Facing Only
Fireplace side
4/23/2021 - 1353
Combustible Facing
Required
1/2" (13mm)
Air Space
Tile Stop
Combustible Facing
Combustible Facing
can be flush with the
Tile Stop on the fireplace
Tile Stop