Coolsmart Tv - Installation Requirements - FireplaceXtrordinair ProBuilder 72 Linear Installation Manual

Table of Contents

Advertisement

CoolSmart TV - Installation Requirements

Upper Manifold Framing
Ceiling
Min. 1-1/2" (39mm)
3-3/4"
(96mm)
Max. 4-1/4"
(108mm)
Max. 120"
(3048mm)
Min. 66-1/2"
(1690mm)
Grill and Manifold Dimensions
The grill may be installed over the facing to
provide an aesthetic opening for the
convection outlet. (2) 8-32 x 1-1/2" screws
attach the trim to the upper manifold. This
allows variable thickness of finish material.
Dimensions
PB 42
45" (1143mm)
PB 54
57" (1448mm)
PB 72
75" (1905mm)
© Travis Industries
Installation
(for qualified installers only)
1-1/4" (32mm)
1-3/4" (45mm)
3/4" (20mm)
Manifold
Manifold Support Bracket
Lower Manifold Framing
Min. 1" (26mm) Clearance from
Flex Duct to Combustibles
Fireplace Header
ProBuilder
Linear
5" (127mm) Alum. Flex Duct (included)
Fireplace
a
b
2-7/8" (74mm)
2-7/8" (74mm)
2-7/8" (74mm)
3/8" (10mm)
Max. 1-1/2" (39mm)
Max. 4-1/4" (108mm)
* This area may be supported using
1" (26mm) strips of non-combustible
material spaced a minimum of 12"
(305mm).
b
a
c
1-1/4" (32mm)
44" (1118mm)
1-1/4" (32mm)
56" (1423mm)
1-1/4" (32mm)
74" (1880mm)
4/21/20 - 1458
Min. 1-1/4" (32mm)
Clearance from Top, Sides
and Back to Combustibles
Min. 3-1/2"
(89mm)
Min. 1/2" (13mm)*
Min. 3-1/2"
(89mm)
Max. 3"
(77mm)
e
d
c
d
e
1-3/4" (45mm)
1-3/4" (45mm)
1-3/4" (45mm)
PB 72 MV/GSB2/GSR2 Install
65

Advertisement

Table of Contents
loading

This manual is also suitable for:

MvProbuilder 72 linear gsb2Probuilder 72 linear gsr2

Table of Contents