Any of E004-0205/E004-0501/E004-0502/E006-0001/E007-9902 was displayed.
- E004-0205: Thermistor temperature difference error
- E004-0501: Fixing main thermistor, a connection error (circuit failure) of fixing sub thermistor 1/2
- E004-0502: Pressure sub thermistor 1/2 connection error (circuit abnormality)
- E006-0001: Fixing feed drawer connection error
- E007-9902: Pressure belt displacement failure (Full displacement of the pressure belt or failure of the
pressure belt position sensor)
Cause
Since the fixing feeder assembly Open/Close switch holder was incorrectly installed, even though the fixing
feeder assembly unit was correctly mounted on the machine during the operation, the sensor detected that
the unit was open, and any of the errors was displayed.
Field Remedy
Go through the following steps.
1) Open the front door, slide out the fixing feeder assembly, and check that the fixing feeder assembly
Open/Close switch holder is correctly installed. If the fixing feeder assembly Open/Close switch holder [1] is
tilted as in the photo [A], remove the screw [2] to reinstall the switch holder in the correct position. The photo
[B] shows the correct position. If the switch holder is deformed or broken, replace the interlock switch unit
(FM3-4952-000).