10) Close the Process Unit Inner Cover [1].
11) Pull out the Fixing Feed Unit and the ITB Unit.
[Caution]
- Be careful not to touch the ITB with fingers or damage it, otherwise failure may occur in the output image.
- Be sure that the ITB Pressure Release Lever is in the horizontal position (released state) to put the ITB
Unit back in the machine. If the unit is pushed in while the ITB Pressure Release Lever is not in the
horizontal position, pressure cannot be applied to the ITB Unit even by turning the ITB Pressure Release
Lever. Operating the machine in this state causes Belt displacement error (E075).
12) Remove the Box Left Cover and the Box Upper Cover, and open the Controller Box.
13) Remove the three screws [2] to remove the flywheel [1].