Manual upload
If you do not wish to switch off the inverter power supply or you do not have an empty
memory card available, you will need to transfer the parameter setting to the memory card
as follows:
Insert a memory card into the Control Unit.
STARTER
4.6.5
Transferring the setting from the memory card
If you wish to transfer the parameter setting from a memory card into the inverter
(download), you have two options:
Automatic download
Switch off the inverter power supply (or disconnect the
Insert the memory card into the inverter.
Then switch the inverter power supply back on again (or
If there is valid parameter data on the memory card, then the inverter accepts this
automatically.
Inverter with CU240B-2 and CU240E-2 Control Units
Operating Instructions, 07/2010, FW 4.3.2, A5E02299792B AA
The Control Unit power supply is switched-on.
Start data transfer with p0971 = 1.
Check the value of parameter p0971.
If data transfer has been completed, p0971 is
automatically set to 0.
Control Unit from the Power Module).
insert the CU onto the Power Module).
4.6 Back-up the settings and transfer
BOP-2
Start data transfer in the menu "OPTIONS" -
"TO CRD".
Wait until the BOP-2 signals that data transfer
has been completed.
Commissioning
89