Technical data
10.3 Technical data, Power Modules
Table 10- 18 Frame sizes B, 3-ph. 380 V ... 480 V AC, ± 10 % - Part 1
Order No.
with filter, IP20
without filter, IP20
with filter, PT
without filter, PT
Values based on Low Overload
● LO power
● LO input current
● LO output current
Values based on High Overload
● HO power
● HO input current
● HO output current
General values
● Power loss
● Fuse
● Cooling air requirement
IP20
● Cable cross-section for line and
motor connection
● Torque for line and
motor connection
● Weight
with filter, IP20
without filter, IP20
with filter, PT
without filter, PT
1) for PT devices 0.24 kW above the heat sink
280
6SL3210-1QE21-0AL0
6SL3210-1QE21-0UL0
10.8 A
0.14 kW
3NA3 805 (16 A)
PT
4.0 ... 6.0 mm
0.5 Nm
3.1 kg
2.9 kg
6SL3210-1QE21-3AL0
6SL3210-1QE21-3UL0
---
---
4 kW
10.2
3 kW
9.3 A
7.7
3NA3 807 (20 A)
9 l/s
9 l/s
4.0 ... 6.0 mm
2
---
---
Operating Instructions, 07/2010, FW 4.3.2, A5E02299792B AA
6SL3210-1QE21-8AL0
6SL3210-1QE21-8UL0
---
6SL3211-1QE21-8AL0
---
6SL3211-1QE21-8UL0
5.5 kW
14 A
13.2
4 kW
12.3 A
10.2
0.19 kW
3NA3 810 (25 A)
9 l/s
9 l/s
2
0.5 Nm
3.1 kg
2.9 kg
---
---
Inverter with CU240B-2 and CU240E-2 Control Units
7.5 kW
19.1 A
18
5.5 kW
15.9 A
13.2
0.27 kW
1)
9 l/s
9 l/s
4.0 ... 6.0 mm
2
0.5 Nm
3.1 kg
2.9 kg
3.6 kg
3.4 kg