D9412GV2/D7412GV2 | Program Entry Guide | 5.0
00:00 is midnight, 23:59 is 11:59 PM. Make entries
using a 24-hour clock (for example, 7:00 AM is
entered as 07:00, 2:45 PM is entered as 14:45).
Reboot the control panel to activate today's window.
The window needs to activate on the same day you
program it.

W# Close Window Start

Default:
00: 00
Selection:
HH:MM (hours and minutes)
Enter the time that you want the control panel to start
the Closing Window. The window goes into effect at
the beginning of the minute.
00:00 is midnight, 23:59 is 11:59 PM. Make entries
using a 24-hour clock (for example, 7:00 AM is
entered as 07:00, 2:45 PM is entered as 14:45).
This program item is one of three required to create a
Closing Window. To program a Closing Window,
Close Early Begin and Close Window Stop must also
be programmed.
If the area is not armed when the Close Window Start
time comes, a warning tone sounds and PLEASE
CLOSE NOW appears at the keypad. To temporarily
silence the tone, press the [ESC] key on the keypad.
The warning tone restarts in 10 minutes if the area is
not armed.
W# Close Early Begin
Refer to the
section for explanations of report features.

W# Close Window Stop

Default:
00: 00
Selection:
HH:MM (hours and minutes)
Enter the time that you want the control panel to end
the Closing Window. The window stops at the end of
the minute.
00:00 is midnight, 23:59 is 11:59 PM. Make entries
using a 24-hour clock (for example, 7:00 AM is
entered as 07:00, 2:45 PM is entered as 14:45).
1
Table 35: W# Close Window Stop Programming Example
W#
Day of Week
1
S M T W T F S
2
S M T W T F S
Bosch Security Systems | 5/05 | F001U003636B
prompt in this
Open
Early
Early
Begin
Start
Stop
Begin
22 : 00
00 : 00
RADXSKED
This program item is one of three required to create a
Closing Window. To program a Closing Window,
Close Early Begin and Close Window Start must also
be programmed.
If the area is not armed by the time the Close Window
Stop time expires, the control panel generates a Fail to
Close Report if enabled in Fail To Close.
Closing Reports generated between the Close Window
Start time and Close Window Stop time can be
suppressed by programming
Window
as Yes. Refer to the
prompt for other explanations of report features.
Do not use a time of 23:59 as a window stop time
unless the window continues on the next day at 00:00.
Fail to Close Reports are not sent, and the Auto Close
feature does not work for windows that stop at 23:59.
Do not program a single window to cross the midnight
boundary. The window stop time must be later than
the window start time. To program a window that
effectively crosses the midnight boundary, you must
program two windows.
For example, to program windows for an area that
closes between 11:30 PM and 12:30 AM, five days a
week, use two windows as shown in Table 35.
Close
eXcept
On
Start
Stop
Holiday
23 : 30
23 : 59
Yes
No
00 : 00
00 : 30
Yes
No
EN | 103
Disable O/C in
W# Close Early Begin
Holiday
Index
Area(s)
1 2 3 4
1 2 3 4 5 6 7 8
1 2 3 4
1 2 3 4 5 6 7 8

Hide quick links: