D9412GV2/D7412GV2 | Program Entry Guide | 2.0
To suppress reports:
Use Opening/Closing Windows to suppress
reports for a specified period of time and then
automatically turn them on again.
Use the Restricted O/C options. A Closing Report
is sent if the user is force arming, sending duress,
or bypass arming. An Opening Report is sent if
the user is disarming during an alarm condition or
unbypasses points when disarming. If the system is
normal, no Opening or Closing Report is sent.
For the scheduled suppression of Opening
and Closing Reports, refer to Section
5.1.1 Opening and Closing) to define
Opening and Closing Windows.
Account Opening and Closing Reports
Opening and Closing Reports are sent by account
when the last area in a group of areas with the same
account number(s) is armed.
Area Opening and Closing Reports
Closing Reports are sent for each area as it is armed.
The account number is also sent for each area.
Customizing Account Opening and Closing Reports
You can eliminate area Opening and Closing Reports
from selected areas in the account by programming
A# Area O/C
as No for those areas.
Combination Account and Area Opening and
Closing Reports
To send both account openings and closings, and
individual area openings and closings for all areas in
the account, you must:
Program

A# Acct O/C

account.
Program
A# Area O/C
account.
Closing Reports: When areas in the account are
independently armed, each area generates an Area
Closing Report. When the last area is armed, it also
generates an Account Closing Report.
Opening Reports: When the first area in the account
is disarmed, it generates an Account Opening Report
along with an Area Opening Report. When the
remaining areas in the account are disarmed, each area
generates an Area Opening Report.
Area Only Opening Closing Supervision Features
Use these features to supervise opening and closing
activity by area. Auto Close, Fail To Open, and Fail
To Close all work independently of the
feature. To use these features, program O/C Windows.
Bosch Security Systems | 5/05 | F001U003636B
as Yes for all areas in the
as Yes for all areas in the
A# Acct O/C
GV2MAIN

Area

Default:
1
Selection:
1 to 8
Enter the area number you are programming.
A# Acct O/C
Default:
No
Selection:
Yes or No
Yes
Send Opening and Closing Reports by
account.
Use this selection if the control panel
sends reports to an automation system
that cannot interpret multiple Area
Opening and Closing Reports, or if
Modem Format
in the Phone category (BFSK format is
used and Opening and Closing Reports
are enabled).
An Account Opening Report is
generated when the first area in an
account is opened (disarmed). After the
Account Opening Report is sent,
disarming other areas in the account
does not generate another Account
Opening Report. An Account Closing
Report is generated only when the last
area in an account is closed (armed).
Opening and Closing Reports for
accounts do not contain any area
information.
Opening and Closing Windows
affect Account Opening and Closing
Reports: If an account opening or
closing is generated while an Opening
or Closing Window for this area is in
effect, and
programmed Yes, the report is not
sent. Use the same opening and closing
window times for all areas sharing the
same account number.
No
Do not send Opening and Closing
Reports by account.
Determines if this area generates Account Opening
and Closing Reports. Program this item the same for
all areas in the account.
EN | 40
is programmed as No
Disable O/C
in Window is