P ## Type
Description
Selection
7*
D279 (O/C Non-Priority): The D279 provides point arming and disarming independent of the
area arm state. A non-priority D279 point arm state does not affect the area arm state.
Response
at the D279, use P## Type 8.
Open the W1 jumper on the D279 to send Point Opening and Point Closing Reports. If the
D279's W1 jumper is closed, no Open or Close Report is sent, regardless of control panel
programming.
Normal:
Open:
Short:
8*
D279 (O/C Priority): The D279 provides point arming and disarming independent of the area's
arming state. A priority D279 point must be armed before an area can be armed. Program
Response
Open the W1 jumper on the D279 to send area Opening and Closing Reports as programmed
in Area Parameters and to provide bell control. If the D279's W1 jumper is closed, no Area
Open or Area Close Report is sent, and alarm bells can only be silenced from a keypad, no
matter how the control panel is programmed.
Normal:
Open:
Short:
9*
Easikey: This point is programmed for access. Program
Master Armed or Perimeter Armed (with or without delays), presenting a valid token to the
Easikey reader shorts the point and disarms its assigned area. Presenting a valid token in a
disarmed state does not clear trouble or alarm memory or rearm the area.
*
Keyswitch Points. Special rules apply to points used for Keyswitch functions. These special point types do not respond
the same way to the point response entry as Point Types 1, 2, and 3. Responses for keyswitch point types are described in
Section 4.2 Point Responses on page 85.
Bosch Security Systems | 5/05 | F001U003636B
must be programmed 1. Local bells are silenced through the keypad. For bell control
The point is armed and sends a Point Closing Report. Point Closing Report is
not sent if
Local Armed
The point is disarmed and sends a Point Opening Report. A Point Opening
Report is not sent if Local Armed is Yes.
A short is an alarm when the point is armed. A short is a trouble when the
point is disarmed. Alarm and Restoral Reports are not sent if
is Yes.
as 2.
When this point changes from open to normal, the area arms.
The area is disarmed. The alarm bell silences if an alarm occurred while the
area was armed.
A short is a trouble while the area is disarmed. A short is an alarm while the
area is armed. When this point changes from shorted to normal or open, it
restores.
RADXPNTS
is Yes.
Point Response
EN | 84
Point
Local Disarmed
Point
as 1. If the system is