A# Area O/C; A# Disable O/C In Window; A# Auto Close; A# Fail To Open - Bosch D9412GV2 Program Entry Manual

Table of Contents

Advertisement

D9412GV2/D7412GV2 | Program Entry Guide | 2.0

A# Area O/C

Default:
Yes
Selection:
Yes or No
Yes
Include the Area # and generate Opening and
Closing Reports for this area when it is armed.
No
Do not include the Area # or generate
Opening and Closing Reports for this area.
Determines if the area number and the account
number are reported at arming and disarming. As long
Account O/C
as
is No, the account number sends a
report when arming this area individually. If
O/C
is Yes, all areas with the same account number
must also be armed.
An Area Opening Report is generated when each area
is opened (disarmed). An Area Closing Report is
generated when each individual area is closed (armed).
Do not program this item as Yes if the
control panel reports to an automation
system that cannot interpret multiple Area
Opening and Closing Reports.

A# Disable O/C in Window

Default:
Yes
Selection:
Yes or No
Yes
Do not send Opening and Closing Reports
to the central station if they occur inside an
active window.
If an Opening or Closing Report occurs
outside a window, send it with an early or
late modifier. Refer to Section 5.1.1 Opening
and Closing on page 99.
The active window must be a Closing
Window for Closing Reports. It must be an
Opening Window for Opening Reports.
No
Send Opening and Closing Reports to the
central station even when they occur inside a
programmed window. If an opening or
closing occurs outside of the appropriate
window, it reports but does not have an
early or late modifier.
If you want to monitor all opening and
closing activity and use features provided by
Opening and Closing Windows, program
this item as No, and program the
appropriate O/C Windows.
Bosch Security Systems | 5/05 | F001U003636B
GV2MAIN
Determines if opening and closing activity is reported
when it occurs inside an Opening or Closing Window,
as programmed in O/C Windows.
Reports are always logged and printed on a local
printer, if installed.

A# Auto Close

Default:
Selection:
Yes
The area automatically master arms at the end
of the Close Window.
When the area is armed automatically, a
Account
Closing Report is sent if the Area or Account
Reports are programmed to do so.
No
Do not automatically arm the area at the end
of the Close Window.
With this program item, the control panel can
automatically master arm the area at the end of the
Closing Window regardless of the previous armed
state.
When an area master arms automatically at
the end of a Close window, the system
disregards the settings in A# Force Arm
Max and P## Bypassable for any faulted
points. The faulted points arm when they
return to normal state.

A# Fail to Open

Default:
Selection:
Yes
No
Use to determine if a Fail to Open Report is sent for
this area. This can determine if a user failed to disarm
the area before the Opening Window expiring.
Normal Opening and Closing Reports do not need to
be programmed to use this feature.
No
Yes or No
No
Yes or No
Fail to Open Report is sent for this
area if the area was not disarmed when
the Opening Window stop time
occurred.
Fail to Open Report is not sent for this
area.