Konica Minolta SONIMAGE HS2 Operation Manual page 230

Ultrasound system
Table of Contents

Advertisement

6 .4 Transferring Image Data
Item
[Clip File Format]
[Clip File Frame Rate]
[Hide patient data]
*: Selectable only when the optional "DICOM Storage License" has been installed .
5
Press the [Export Image] button on the [Export Image] screen to execute .
• Images are output to an external storage medium .
6
Upon completion of the output, touch the SD memory card icon in the status indicator area .
• A message appears in the pop-up window, confirming that the external storage medium can be safely re-
moved .
7
Select the Remove icon
the SD memory card .
• The SD memory card icon is hidden .
HINT
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
• In the [Other] tab of the menu pop-up window, you can use
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Selects an output format of a clip file.
[Type 1(* .avi)]
• Outputs in * .avi format . Suitable for playback on monitors for medical use that have applied
GSDF (DICOM curve) .
[Type 2(* .mp4)]
• Outputs in * .mp4 format . Perfect for playback on typical computer monitors and it is the small-
est file size.
[Type 3(* .avi)]
• Outputs in * .avi format . Suitable for playback on typical computer monitors .
Select this if playback cannot be done using the Type 2 format .
[DICOM(DCM)]*
• This is set if the [Export Image] is in [DICOM Format] .
Detailed formats to output depend on the [Contrast Compensation] of the DICOM media stor-
age . For details, refer to "DICOM Screen" of the "Operation Manual: Applications" .
Selects and changes the frame rate of a clip file.
Sets whether to mask the patient information of the image and output .
• Mark the check box to mask and output the patient information .
• If, with the check box marked, an uneditable image is included in the output, a message appears,
confirming that there is an image to be output without masking the patient information. Then you
are prompted to choose between continuing the operation and canceling it .
for SD memory card desired to be removed and then remove
Functions
to write image data .
230

Advertisement

Table of Contents
loading

Related Products for Konica Minolta SONIMAGE HS2

Table of Contents