Connecting Dc Power Cables To The Acx2000 Or Acx2100 Router - Juniper ACX2000 Hardware Manual

Hide thumbs Also See for ACX2000:
Table of Contents

Advertisement

Connecting DC Power Cables to the ACX2000 or ACX2100 Router

To connect power to the router, you need the following tools:
Phillips (+) screwdriver, number 2
ESD grounding wrist strap
M3 screws and flat washers
DC power source cables, minimum 14 AWG or as required by local code (not provided)
Ring lugs, Molex 190700067 or equivalent (not provided)
The DC power supply has four terminals on the front panel, covered by a clear plastic cover.
WARNING:
To connect the power cables:
1. Switch off the dedicated customer site circuit breakers. Ensure that the voltage across the DC power
source cable leads is 0 V and that there is no chance that the cable leads might become active during
installation.
2. Remove the clear plastic cover protecting the terminal on the faceplate.
3. Verify that the DC power cables are correctly labeled before making connections to the power supply.
In a typical power distribution scheme where the return is connected to chassis ground at the battery
plant, you can use a multimeter to verify the resistance of the –48V and return DC cables to chassis
ground:
For –48V and –60V:
a. The cable with very large resistance (indicating an open circuit) to chassis ground is the DC input
cable (–).
b. The cable with very low resistance (indicating a closed circuit) to chassis ground is the return cable
(+).
For +24V:
a. The cable with very low resistance (indicating a closed circuit) to chassis ground is the DC input
cable (–).
b. The cable with very large resistance (indicating an open circuit) to chassis ground is the return cable
(+).
You must ground the router before connecting the DC power cables.
102

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acx2100

Table of Contents