Juniper ACX2000 Hardware Manual page 101

Hide thumbs Also See for ACX2000:
Table of Contents

Advertisement

CAUTION:
the grounding points as you are tightening the screws. Ensure that each screw is
properly threaded into the grounding points. Applying installation torque to the
screw when improperly threaded may result in damage to the terminal.
CAUTION:
4 lb-in. (0.49 Nm). The grounding screws may be damaged if excessive torque is
applied. Use only a torque-controlled driver to tighten screws. Use an appropriately
sized driver, with a maximum torque capacity of 5 lb-in. or less. Ensure that the
driver is undamaged and properly calibrated and that you have been trained in its
use. You may wish to use a driver that is designed to prevent overtorque when the
preset torque level is achieved.
9. Dress the grounding cable, and verify that it does not touch or block access to router components, and
that it does not drape where people could trip on it.
Figure 21: Grounding Points on the ACX2000 and ACX2100 Router
1
Grounding lug
SEE ALSO
Installing and Connecting an ACX2000 or ACX2100 Router Overview | 93
ACX2000 and ACX2100 Power Overview | 62
ACX2000 and ACX2100 Chassis Grounding Cable and Lug Specifications | 74
Prevention of Electrostatic Discharge Damage | 168
Ensure that each grounding cable lug seats flush against the surface of
The maximum torque rating of the grounding screws on the router is
1
2
2
SAE 10-32 screws and washers
101

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acx2100

Table of Contents