Ricoh Aficio 1515 Service Manual page 253

Hide thumbs Also See for Aficio 1515:
Table of Contents

Advertisement

9 March 2004
G3-1 Switch 0B
No
FUNCTION
0
Protocol requirements: Europe
0: Disabled 1: Enabled
1
Protocol requirements: Spain
0: Disabled 1: Enabled
2
Not used
3
Protocol requirements: France
0: Disabled 1: Enabled
4
PTT requirements: Germany
0: Disabled 1: Enabled
5-7
Not used
G3-1 Switch 0C
No
FUNCTION
0
Pulse dialing method
to
Bit 1 Bit 0
Setting
1
0
0
Normal (P=N)
0
1
Oslo (P=10 - N)
1
0
Sweden (N + 1)
1
1
Not used
2-7
Not used
G3-1 Switch 0D - Not used (Do not change the settings.)
G3-1 Switch 0E
No
FUNCTION
0
CNG transmission OFF interval.
to
To input a value more than 3 s, use
7
bits 3 to 0, and keep bits 4 to 7 at 0.
3000 + 50 x N ms
To inpu a value less than 3 s, use bits
4 to 7, and keep bits 0 to 3 at 1.
3000 – 50 x N ms
COMMENTS
The machine does not automatically reset these bits
for each country after a country code (System
Switch 0F) is programmed.
Change the required bits manually at installation.
Do not change the setting.
The machine does not automatically reset these bits
for each country after a country code (System
Switch 0F) is programmed.
Change the required bits manually at installation.
Do not change the settings.
COMMENTS
P = Number of pulses sent out, N = Number dialed.
Do not change the settings.
Examples:
3100 ms: 50 x 2 = 100
Bits 4 to 7 must be 0
Bits 0 to 3 must be 2(H)
So, enter 02H.
2800 ms: 50 x 4 = 200
Bits 0 to 3 must be F(H)
Bits 4 to 7 must be 4(H)
So, enter 4FH
3-33
BIT SWITCHES
SP No. 1-105-012
SP No. 1-105-013
SP No. 1-105-015
COMMENTS