ERROR CODES
Code
Meaning
2-51
The machine resets itself
because of a fatal
communication error
4-01
Line current was cut
4-10
Communication failed
because of an ID Code
mismatch (Closed Network)
or Tel. No./CSI mismatch
(Protection against Wrong
Connections)
5-00
Data construction not
possible
5-10
DCR timer expired
5-20
Storage impossible because
of a lack of memory
5-21
Memory overflow
5-23
Print data error when
printing a substitute rx or
confidential rx message
5-25
SAF file access error
6-00
G3 ECM - T1 time out
during reception of facsimile
data
6-01
G3 ECM - no V.21 signal
was received
6-02
G3 ECM - EOR was
received
6-04
G3 ECM - RTC not detected
6-05
G3 ECM - facsimile data
frame not received within 18
s of CFR, but there was no
line fail
6-06
G3 ECM - coding/decoding
error
6-08
G3 ECM - PIP/PIN received
in reply to PPS.NULL
6-09
G3 ECM - ERR received
Suggested Cause/Action
• If this is frequent, update the ROM, or replace the
FCU.
• Check the line connector.
• Check for line problems.
• Replace the FCU.
• Get the ID Codes the same and/or the CSIs
programmed correctly, then resend.
• The machine at the other end may be defective.
• Replace the FCU.
• Temporary memory shortage.
• Test the SAF memory.
• Replace the FCU or optional EXMEM board
• Test the SAF memory.
• Ask the other end to resend the message.
• Replace the FCU.
• Replace the FCU.
• Try adjusting the rx cable equalizer.
• Replace the FCU.
• Check the line connection.
• Check connections from the NCU to the FCU.
• Check for a bad line or defective remote terminal.
• Replace the FCU.
• Check the line connection.
• Check for a bad line or defective remote terminal.
• Replace the FCU.
• Try adjusting the rx cable equalizer
Cross reference
• Rx cable equalizer - G3 Switch 07 (PSTN)
• Defective FCU.
• The other terminal may be defective.
• The other end pressed Stop during
communication.
• The other terminal may be defective.
• Check for a noisy line.
• Adjust the tx levels of the communicating
machines.
• See code 6-05.