9 March 2004
2929*
Vref Limits
2929 1
Upper
2929 2
Lower
2994*
ID Sensor Detection Temperature
2994 1
Adjusts the temperature threshold. The ID sensor signal is not referenced when the
fusing temperature is at the specified level or higher while the copier is recovering
or starting up.
2996*
Transfer Roller Cleaning
Cleans or does not clean the transfer roller before each job. Select "1" if the
2996 1
backside of the paper becomes unclean when output. Note that the copier takes a
longer time to output the first copy when you select "1". If you select "0," the transfer
roller is never cleaned.
2998*
Main Scan Magnification
2998 1
Adjusts the magnification (☛ 3.14). The specification is 100 ± 1.0%.
Adjust the upper or lower Vref limit.
[0.50 ~ 3.50 / 3.20 / 0.01V/step] DFU
[0.50 ~ 3.50 / 0.70 / 0.01V/step] DFU
[30 ~ 90 / 30 / 1 °C/step]
[0 = No / 1 = Yes]
[–0.5 ~ +0.5 / 0.0 / 0.1%/step]