9 March 2004
System Switch 02
No
FUNCTION
0-1
Not used
2
Communication stall fail safe.
0: Disabled
1: Enabled
3-4
Not used.
5
Not used
6
Memory read/write by RDS
to
Bit 7
6
Setting
7
0
0
Always disabled
0
1
User selectable
1
0
User selectable
1
1
Always enabled
System Switch 03
No
FUNCTION
0
Length of time that RDS is
to
temporarily switched on when
7
bits 6 and 7 of System Switch
02 are set to "User selectable"
System Switch 04
No
FUNCTION
0-2
Not used
3
Printing dedicated tx
parameters on Quick Dial Lists
0: Disabled
1: Enabled
4-7
Not used
System Switch 05 - Not used (Do not change the factory settings.)
System Switch 06 - Not used (Do not change the factory settings.)
System Switch 07 - Not used (Do not change the factory settings.)
System Switch 08 - Not used (Do not change the factory settings.)
COMMENTS
Do not change the settings.
If enabled, the machine cuts communication within
one hour of a communication error but the
connection remains established.
Do not change the settings.
Do not change the setting.
(0,0): All RDS systems are always locked out.
(0,1), (1,0): Normally, RDS systems are locked out,
but the user can temporarily switch RDS on to allow
RDS operations to take place. RDS will
automatically be locked out again after a certain
time, which is stored in System Switch 03. Note that
if an RDS operation takes place, RDS will not switch
off until this time limit has expired.
(1,1): At any time, an RDS system can access the
machine.
COMMENTS
00 - 99 hours (BCD).
This setting is only valid if bits 6 and 7 of System
Switch 02 are set to "User selectable".
The default setting is 24 hours.
COMMENTS
Do not change the settings.
1: Each Quick dial number on the list is printed with
the dedicated tx parameters (10 bytes each).
The first 10 bytes of data are the programmed
dedicated tx parameters; 34 bytes of data are
printed (the other 24 bytes have no use for service
technicians).
Do not change the settings.
3-9
BIT SWITCHES
SP No. 1-101-003
SP No. 1-101-004
SP No. 1-101-005