Ricoh Aficio 1515 Service Manual page 216

Hide thumbs Also See for Aficio 1515:
Table of Contents

Advertisement

9 March 2004
Code
Meaning
0-83
The line was disconnected
due to a timeout in the V.34
control channel restart
sequence.
0-84
The line was disconnected
due to abnormal signaling in
V.34 phase 4 – control
channel start-up.
0-85
The line was disconnected
due to abnormal signaling in
V.34 control channel restart.
0-86
The line was disconnected
because the other terminal
requested a data rate using
MPh that was not available
in the currently selected
symbol rate.
0-87
The control channel started
after an unsuccessful
primary channel.
0-88
The line was disconnected
because PPR was
transmitted/received 9
(default) times within the
same ECM frame.
2-10
The modem cannot enter tx
mode
2-11
Only one V.21 connection
flag was received
2-12
Modem clock irregularity
2-13
Modem initialization error
2-23
JBIG compression or
reconstruction error
2-24
JBIG ASIC error
2-25
JBIG data reconstruction
error (BIH error)
2-26
JBIG data reconstruction
error (Float marker error)
2-27
JBIG data reconstruction
error (End marker error)
2-28
JBIG data reconstruction
error (Timeout)
2-50
The machine resets itself for
a fatal FCU system error
Suggested Cause/Action
If these errors happen at the receiving terminal:
• Try adjusting the rx cable equalizer setting.
• Try increasing the tx level.
• Try using V.17 or a slower modem if the same
error is frequent when receiving from multiple
senders.
• The signal did not stop within 10 s.
• Turn off the machine, then turn it back on.
• If the same error is frequent, replace the FCU.
• The signal did not stop within 10 s.
• Turn off the machine, then turn it back on.
• If the same error is frequent, replace the FCU.
• The other terminal was incompatible.
• Ask the other party to contact the manufacturer.
• The receiving terminal restarted the control
channel because data reception in the primary
channel was not successful.
• This does not result in an error communication.
• Try using a lower data rate at the start.
• Try adjusting the cable equalizer setting.
• Replace the FCU.
• Replace the FCU.
• Replace the FCU.
• Turn off the machine, then turn it back on.
• Replace the FCU.
• Turn off the machine, then turn it back on.
• Turn off the machine, then turn it back on.
• JBIG data error
• Check the sender's JBIG function.
• Update the MBU ROM.
• If this is frequent, update the ROM, or replace the
FCU.