535-8001-02
Detection Description
Remedy
535-8002-02
Detection Description
Remedy
Error in the Swing Guide Motor (Finisher-Y1)
The swing guide does not come off the Swing Guide HP Sensor when the Swing Guide Motor has
been driven for 1 second.
STAPLE FIN-Y1/BOOKLET FIN-Y1
[Related parts]
- Harnesses from the Swing Guide HP Sensor (PS119) to the Finisher Controller PCB
- Harnesses from the Swing Guide Motor (M110) to the Finisher Controller PCB
- Swing Guide HP Sensor (PS119)
- Swing Guide Motor (M110)
- Finisher Controller PCB (PCB101)
[Points to note at work] When the Swing Guide Safety Switch (SW102) turns on at the detection
timing of this error, this error code may be displayed. Accordingly, perform the following work before
checking the related parts.
1. Check whether there is not the malfunction in the swing guide unit.
2. Check whether there is not the malfunction in the Swing Guide Safety Switch (SW102).
[Remedy] Check/replace the related harness/cable, connector and parts.
[Reference] When replacing the Finisher Controller PCB, refer to "Adjustment> When Replacing
the Parts" in the Service Manual.
Error in the Swing Guide Motor (Finisher-Y1)
The Swing Guide HP Sensor does not detect the swing guide when the Swing Guide Motor has
been driven for 1 second.
STAPLE FIN-Y1/BOOKLET FIN-Y1
[Related parts]
- Harnesses from the Swing Guide HP Sensor (PS119) to the Finisher Controller PCB
- Harnesses from the Swing Guide Motor (M110) to the Finisher Controller PCB
- Swing Guide HP Sensor (PS119)
- Swing Guide Motor (M110)
- Finisher Controller PCB (PCB101)
[Points to note at work] When the Swing Guide Safety Switch (SW102) turns on at the detection
timing of this error, this error code may be displayed. Accordingly, perform the following work before
checking the related parts.
1. Check whether there is not the mulfunction in the swing guide unit.
2. Check whether there is not the mulfunction in the Swing Guide Safety Switch (SW102).
[Remedy] Check/replace the related harness/cable, connector and parts.
[Reference] When replacing the Finisher Controller PCB, refer to "Adjustment> When Replacing
the Parts" in the Service Manual.