Menu "Parsb" (3+8), Parameters Sunny Boy - SMA Sunny Island SI3300 Installation & Operating Instructions Manual

Bidirectional battery inverter for stand-alone applications
Table of Contents

Advertisement

Sunny Island

8.8 Menu "PARSB" (3+8), Parameters Sunny Boy

This menu can only be selected after the installer password (level: 1) has been en-
tered.
You should define settings in the menu "PARSB" (3+8) if there are Sunny Boy in-
verters in the island grid which are to be controlled by the Sunny Island via the
RS485 interface (COM2).
"PARSB" (3+8)
Name
801_Sunny Boys
Table 8.7: Settings in the menu "PARSB" (3+8)
BWRI33-12:EE
Fig. 8.11: Menu "PARSB" (3+8)
Description
Not installed:
Sunny Island is not to control Sunny Boys.
Installed:
Sunny Island is to control Sunny Boys.
Inst. Mains:
Sunny Island is to control Sunny Boys only if grid
feeding is not possible.
- 95 -
Installation & Operating Instructions
SMA Regelsysteme GmbH

Advertisement

Table of Contents
loading

Table of Contents