Connection To Ac Voltage - SMA Sunny Island SI3300 Installation & Operating Instructions Manual

Bidirectional battery inverter for stand-alone applications
Table of Contents

Advertisement

Sunny Island
If a battery temperature sensor is installed later, the Sunny Island will
only detect it after a restart!

3.4.4 Connection to AC Voltage

On the power side the AC voltage is connected to the automatic circuit breaker F2. If
there is only one electric circuit this can be directly supplied by the Sunny Island. If
there are additional devices feeding the grid, such as wind generators, separate cir-
cuits and thus an external distribution is recommended.
AC-
F2
Outlet
Sunny Island
Direct consumer
Fig. 3.7 shows an exemplary layout of a subdistribution if additional electric circuits
and grid-feeding devices are integrated into the system.
BWRI33-12:EE
N
L
or
Fig. 3.7: AC voltage connection
- 29 -
Installation & Operating Instructions
External distribution
6 A
6 A
L
N
G
SMA Regelsysteme GmbH

Advertisement