SMA Sunny Island SI3300 Installation & Operating Instructions Manual page 143

Bidirectional battery inverter for stand-alone applications
Table of Contents

Advertisement

Sunny Island
„PARALL" (3+9)
Parameter
Unit Min. Max.
712_K1 On t1
713_K1 Off t1
714_K1 On t2
715_K1 Off t2
716_K2 t2 begin
717_K2 t2 end
718_K2 On t1
719_K2 Off t1
720_K2 On t2
721_K2 Off t2
722_K3 t2 begin
BWRI33-12:EE
Default
0
10
5
0
10
5
0
10
5
0
10
5
h
0
23
0
h
0
23
0
0
10
5
0
10
5
0
10
5
0
10
5
h
0
23
0
Installation & Operating Instructions
Description
When this battery state is reached, K1 is switched
on.
0: L4
deep-cycle discharge
1: L3
2: L2
3: L1
4: N4
5: N3
6: N2
7: N1
Battery full
8: O1
Overcharge
9: O2
10: O3
When this battery state is reached, K1 is switched
off.
0: L4
deep-cycle discharge
1: L3
2: L2
3: L1
4: N4
5: N3
6: N2
7: N1
Battery full
8: O1
Overcharge
9: O2
10: O3
Switch-on threshold for K1 in special period t2 (see
712)
Switch-off threshold for K1 in special period t2 (see
713)
Beginning of special period t2 for K2 (see 710)
End of special period t2 for K2 (see 711)
Switch-on threshold for K2 (see 712)
Switch-off threshold for K2 (see 713)
Switch-on threshold for K2 in special period t2
(see 714)
Switch-off threshold for K2 in special period t2
(see 715)
Beginning of special period t2 for K3 (see 710)
- 143 -
SMA Regelsysteme GmbH

Advertisement