Siemens SIMATIC ET 200pro FC-2 Operating Instructions Manual page 56

Low voltage converter for the distributed i/o system
Hide thumbs Also See for SIMATIC ET 200pro FC-2:
Table of Contents

Advertisement

Installation
4.10 Wiring the ET200pro system
Table 4- 3
Number
1
2
3
4
5
6
7
8
Requirements
Note
National Fire Protection Association (NFPA) compatibility
These devices are only certified for installation in industrial machines in accordance with the
"Electrical Standard for Industrial Machinery" (NFPA79).
Due to their design features, it is possible that these devices cannot be installed in
accordance with the National Electrical Code (NFPA70).
Note
It is only permissible to use temperature-resistant copper cables for at least 75 °C.
54
Assignment of the main power connections on the frequency converter
Connection X1
HAN Q4/2 (male)
Phase L1
Phase L2
Phase L3
Not assigned
--
--
--
--
PE
Connection X2
HAN Q8/0 (female)
U
Not assigned
W
Brake (-)
Temperature sensor (+)
Brake (+)
V
Temperature sensor (-)
PE
Operating Instructions, 04/2018, FW V4.7 SP10, A5E34257324B AF
Connection X3
HAN Q4/2 (female)
Phase L1
Phase L2
Phase L3
Not assigned
--
--
--
--
PE
SIMATIC ET 200pro FC-2 converter