Siemens SIMATIC ET 200pro FC-2 Operating Instructions Manual page 30

Low voltage converter for the distributed i/o system
Hide thumbs Also See for SIMATIC ET 200pro FC-2:
Table of Contents

Advertisement

Description
3.2 Components for assembling a frequency converter
ET 200pro FC-2 with F-Switch
Figure 3-2
Setup the Safe Torque Off (STO) function using PROFIsafe.
Table 3- 2
No.
1
2
3
4
28
ET 200pro FC-2 with F-Switch
Components of the ET 200pro FC-2 with F-Switch
Components
Function
Mounting rail
The mounting rail is used to secure all the components of the ET
200pro system easily and allows the components to be connected to
each other efficiently and accurately.
Connection modules
The connection modules are mounted on the interface modules. The
for interface mod-
modules are designed to allow a variety of connections types suitable
ules
for a number of applications.
The follow connection modules are available:
PROFINET interface
The interface module interconnects the ET 200pro with the
module with bus
PROFINET master and prepares the data for the electronic mod-
module
ules.The unit is delivered with the terminating module. The interface
module is already mounted on the bus module.The bus module is the
mechanical and electrical connection element between the various
ET 200pro modules.The terminating module terminates the
ET 200pro.The following interface modules are available for
PROFINET IO:
F-Switch with bus
The F-Switch is used in conjunction with the converter only for the
module
purpose of switching control signals from the higher-level controller
through PROFIsafe onto the internal switch-off signals F0 and F1 on
the ET 200pro backplane bus.
Direct connection:
CM IM DP Direct
ECOFAST:
CM IM DP ECOFAST CU
CM IM DP M12, 7/8"
IM154-4 PN
IM154-6 PN
Operating Instructions, 04/2018, FW V4.7 SP10, A5E34257324B AF
SIMATIC ET 200pro FC-2 converter

Advertisement

Table of Contents
loading