Siemens SIMATIC ET 200pro FC-2 Operating Instructions Manual page 256

Low voltage converter for the distributed i/o system
Hide thumbs Also See for SIMATIC ET 200pro FC-2:
Table of Contents

Advertisement

Technical data
11.5 Electromagnetic compatibility of the converters
EMC phenomena
High-frequency electromagnetic field,
amplitude-modulated
The requirements of the generic standards in respect of interference immunity are met. The
required values for interference emission are complied with if installation takes place
according to EMC installation guidelines.
254
Basic standard for
Level
test procedures
1 kV electric power cable (phase
- phase)
1 kV control cable (cable -
ground)
EN 61000-4-3
80 MHz – 1000 MHz, 10 V/m,
80 % AM
Operating Instructions, 04/2018, FW V4.7 SP10, A5E34257324B AF
Evaluation criterion
B
B
A
SIMATIC ET 200pro FC-2 converter

Advertisement

Table of Contents
loading

Table of Contents