Alarms, faults and system messages
10.2 Diagnostics through fieldbus
Diagnostics with Profinet
PROFINET uses the channel diagnostics to transfer PROFIdrive message classes.
0002 hex
Undervoltage
0003 hex
Overvoltage
0005 hex
Overtemperature
0009 hex
Error
0010 hex
Parameterization error
0013 hex
Communication error
Reading out diagnostics data
The control requests the diagnostics data from the inverter using "Read data set", e.g. using
a read record with index 800C hex.
226
0014 hex
Ground fault
0018 hex
Actuator disconnection
0019 hex
Safety-related shutdown
001A hex
External fault
001D hex
Fault 1 in actuator/sensor
001F hex
Channel temporarily not available
Operating Instructions, 04/2018, FW V4.7 SP10, A5E34257324B AF