Siemens SIMATIC ET 200pro FC-2 Operating Instructions Manual page 109

Low voltage converter for the distributed i/o system
Hide thumbs Also See for SIMATIC ET 200pro FC-2:
Table of Contents

Advertisement

Error
Meaning
value 1
73 hex
Change request possible only during commissioning of the safety functions (p0010 = 95).
74 hex
Change request is only possible when a technological application/unit is being commissioned (p0010 = 5).
75 hex
Change request is only possible in a commissioning state (p0010 ≠ 0).
76 hex
Change request is not possible for internal reasons (p0010 = 29).
77 hex
Change request is not possible during download.
81 hex
Change request is not possible during download.
82 hex
Accepting the master control is inhibited via BI: p0806.
83 hex
Desired interconnection is not possible(the connector output does not supply a float value although the con-
nector input requires a float value)
84 hex
Inverter does not accept a change request (inverter is busy with internal calculations. See parameter r3996 in
the inverter List Manual.
Manuals for your inverter (Page 272))
85 hex
No access methods defined.
86 hex
Write access only during commissioning of the data records (p0010 = 15) (operating status of the inverter pre-
vents a parameter change.)
87 hex
Know-how protection active, access locked
C8 hex
Change request below the currently valid limit (change request to a value that lies within the "absolute" limits,
but is however below the currently valid lower limit)
C9 hex
Change request above the currently valid limit(example: a parameter value is too large for the inverter power)
CC hex
Change request not permitted (change is not permitted as the access code is not available)
See also
STEP 7 program example for acyclic communication (Page 258)
SIMATIC ET 200pro FC-2 converter
Operating Instructions, 04/2018, FW V4.7 SP10, A5E34257324B AF