3.1.3.3

Sensor Module Cabinet SMC30

Table 3- 35
Meaning of LEDs on the Sensor Module Cabinet SMC30
LED
Color
RDY
READY
Green
Orange
Red
Green/red
Green/red
Green/
orange
or
Red/orange
OUT >
5 V
Orange
Commissioning Manual
Commissioning Manual, (IH1), 01/2013, 6SL3097-4AF00-0BP3
State
Description, cause
Off
Electronic power supply is missing or outside permissible
tolerance range.
Continuous
The component is ready for operation and cyclic DRIVE-
light
CLiQ communication is taking place.
Continuous
DRIVE-CLiQ communication is being established.
light
Continuous
This component has at least one fault.
light
Note:
LED is controlled irrespective of the corresponding messages
being reconfigured.
Flashing light
Firmware is being downloaded.
0.5 Hz
Flashing light
Firmware download is complete. Wait for POWER ON.
2 Hz
Flashing light
Component recognition via LED is activated (p0144).
Note:
Both options depend on the LED status when module
recognition is activated via p0144 = 1.
Off
Electronic power supply is missing or outside permissible
tolerance range.
Power supply ≤ 5 V.
Continuous
Electronics power supply for encoder system available.
light
Power supply > 5 V.
Notice
Make sure that the connected encoder can be operated with
a 24 V power supply. If an encoder that is designed for a 5 V
supply is operated with a 24 V supply, this can destroy the
encoder electronics.
Diagnostics
3.1 Diagnostics via LEDs
Remedy
Remedy and
acknowledge fault
Carry out a
POWER ON
263