Commissioning
2.3 Creating a project in the STARTER commissioning tool
What?
2. Add individual drive
3. Configure the drive unit
82
How?
1. Double-click in the project tree on "Insert single drive unit".
The following settings are pre-assigned:
Device type: CU320-2 DP
Device version: 4.5 or higher
Address type: PROFIBUS/USS/PPI
Bus address: 7
2. If necessary, correct these settings.
Once you have created the project, you have to configure the drive unit. Some examples are
provided in the following Chapters.
Commissioning Manual, (IH1), 01/2013, 6SL3097-4AF00-0BP3
Comment
Information about the bus
address:
The PROFIBUS address of
the Control Unit must be
set for initial
commissioning.
Using the rotary coding
switches on the Control
Unit, the address can be
set to a value between 1
and 126 and read via
p0918. If the coding
switches are at "0" (factory
setting), the value can be
alternatively set between 1
and 126 using p0918.
Commissioning Manual