Encoder type
Absolute value
linear
HTL/TTL
Incremental
encoders
square wave
rotary
SSI encoder
Absolute value
absolute
rotary
SSI encoder
Absolute value
absolute HTL
rotary
Linear
Incremental
encoder
linear
SIMAG H2
Incremental
encoder
rotary
Note
The SMC40 can only be completely configured, if an associated EnDat 2.2 encoder is
connected. Without a connected encoder, it is not possible to integrate the SMC40 into the
topology.
Commissioning Manual
Commissioning Manual, (IH1), 01/2013, 6SL3097-4AF00-0BP3
Encoder code Encoder evaluation procedure
2151
16000 nm, 1 Vpp, A/B, EnDat,
resolution 100 nm
3001
1024 HTL A/B R
3002
1024 TTL A/B R
3003
2048 HTL A/B R
3005
1024 HTL A/B
3006
1024 TTL A/B
3007
2048 HTL A/B
3008
2048 TTL A/B
3009
1024 HTL A/B unipolar
3011
2048 HTL A/B unipolar
3020
2048 TTL A/B R, with Sense
3081
SSI, singleturn, 24 V
3082
SSI, multiturn 4096, 24 V
Not for motor control,
only as a direct measurement system
3090
4096, HTL, A/B, SSI, singleturn
3109
2000 nm, TTL, A/B R distance-coded
2002
2048, 1 Vpp, A/B R
2003
256, 1 Vpp, A/B R
2004
400, 1 Vpp, A/B R
2005
512, 1 Vpp, A/B R
2006
192, 1 Vpp, A/B R
2007
480, 1 Vpp, A/B R
2008
800, 1 Vpp, A/B R
2.11 Selection and configuration of encoders
Commissioning
Evaluation module
SMC20, SMI20,
SME25
SMC30
SMC20, SMI20,
SME25, SME125
SMC30
SMC20, SMI20,
SME20
SMC20, SMI20,
SME20
141