Voltage Sensing Module VSM10

Table 3- 41
Meanings of the LEDs on the Voltage Sensing Module VSM10
LED
Color
READY
Green
Orange
Red
Green/red
Green/
orange or
Red/
orange
3.1.3.8

DRIVE-CLiQ Hub Module DMC20

Table 3- 42
Description of the LEDs on the DRIVE-CLiQ Hub Module DMC20
LED
Color
READY
Green
Orange
Red
Green/red
Commissioning Manual
Commissioning Manual, (IH1), 01/2013, 6SL3097-4AF00-0BP3
State
Description, cause
Off
Electronic power supply is missing or outside permissible
tolerance range.
Continuous
The component is ready for operation and cyclic DRIVE-
light
CLiQ communication is taking place.
Continuous
DRIVE-CLiQ communication is being established.
light
Continuous
This component has at least one fault.
light
Note:
LED is controlled irrespective of the corresponding messages
being reconfigured.
Flashing light
Firmware is being downloaded.
0.5 Hz
Flashing light
Firmware download is complete. Wait for POWER ON
2 Hz
Flashing light
Component recognition via LED is activated (p0144).
Note:
Both options depend on the LED status when module
recognition is activated via p0144 = 1.
State
Description, cause
Off
Electronic power supply is missing or outside permissible
tolerance range.
Continuous
The component is ready for operation and cyclic DRIVE-
light
CLiQ communication is taking place.
Continuous
DRIVE-CLiQ communication is being established.
light
Continuous
This component has at least one fault.
light
Note:
LED is controlled irrespective of the corresponding messages
being reconfigured.
Flashing light
Firmware is being downloaded.
0.5 Hz
Flashing light
Firmware download is complete. Wait for POWER ON
2 Hz
Diagnostics
3.1 Diagnostics via LEDs
Remedy
Remedy and
acknowledge fault
Carry out a
POWER ON
Remedy
Remedy and
acknowledge fault
Carry out a
POWER ON