Siemens SINAMICS S120 Commissioning Manual page 71

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Install online operation via Ethernet
1. Install the Ethernet interface in the programming device according to the manufacturer's
2. Set the IP address of the Ethernet interface in Windows XP:
3. Set the access point of the STARTER commissioning tool.
4. Using the STARTER commissioning tool, specify a name for the Control Unit interface.
Setting the IP address in Windows XP
1. On the desktop, click on the symbol "Network Environment" and click the right mouse
2. Double-click the appropriate network card and then click "Properties".
3. Select the Internet Protocol (TCP/IP) and click the "Properties" button.
4. Then enter IPs for the "IP address" and the "Subnet mask".
Commissioning Manual
Commissioning Manual, (IH1), 01/2013, 6SL3097-4AF00-0BP3
instructions.
– Assign the programming device a free IP address (e.g. 169.254.11.1).
– In the delivery condition, the IP address of the internal Ethernet interface X127 of the
Control Unit is 169.254.11.22.
button to open the "Properties" shortcut menu.
Figure 2-6
Setting the IP address from the PG/PC
Commissioning
2.2 STARTER commissioning tool
69