SINAMICS parameters
7.1 SINAMICS V70 parameters
Par. No.
Name
p1661
Current setpoint filter 1 nu‐
merator damping
Description: Sets the numerator damping for current setpoint filter 1.
Dependency: Current setpoint filter 1 is activated via p1656.0 and parameterized via p1657 ... p1661.
r2114[0...1]
System runtime total
Description: Displays the total system runtime for the drive unit.
The time comprises r2114[0] (milliseconds) and r2114[1] (days).
After r2114[0] has reached a value of 86.400.000 ms (24 hours) this value is reset and r2114[1] is incre‐
mented.
● [0] = Milliseconds
● [1] = Days
p2153
Speed actual value filter
time constant
Description: Sets the time constant of the PT1 element to smooth the speed/velocity actual value.
The smoothed actual speed/velocity is compared with the threshold values and is only used for messages
and signals.
p29000
Motor type selection
Description: Motor type number is printed on the motor rating plate as motor ID. For a motor with an incre‐
mental encoder, you need to manually input the parameter value, ranging from 18 to 39. For a motor with
an absolute encoder, the drive reads the parameter value automatically, ranging from 10009 to 10048.
p29002
BOP operating display se‐
lection
Description: BOP operating display selection.
● 0: Actual speed
● 1: DC voltage
● 2: Actual torque
r29018[0...1]
Firmware version
Description: Firmware version.
● [0]: Firmware version number
● [1]: Build increment number
Note:
Index [1] only applies to V70 firmware versions higher than 1.00.
For example, when r29018[0] = 10100 and r29018[1] = 10, the firmware version is displayed as 1.01.00.10
on the HMI.
7.1.2

Drive basic list on HMI

The drive basic list on HMI contains the most frequently used drive parameters for
commissioning. You can also view them through the following operations:
518
Min
Max
Factory
setting
0.000
10.000
0.700
-
-
-
0
1000000
0
0
54251
-
0
2
0
-
-
-
Unit
Data type
Effective
-
Float
IM
-
U32
-
ms
Float
IM
-
U16
IM
-
U16
IM
-
U32
-
List Manual, 01/2017
Can be
changed
T, U
-
T, U
T
T, U
-
Parameter Manual