Technical Specifications; Line Filters For Smart Line Modules; Description - Siemens SINAMICS S120 Equipment Manual

Booksize power sections cold plate
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Line Connection

4.5 Line filters for Smart Line Modules

4.4.5

Technical Specifications

Table 4-7
Technical specifications: Wideband Line Filter for Active Line Modules
Rated power
Connection voltages:
Supply voltage
Line frequency
Rated current
Power loss
1
Weight
1 For an overview, see the power loss tables in Cabinet Design.
4.5
Line filters for Smart Line Modules
4.5
4.5.1

Description

The line filters for Smart Line Modules are designed for use in machines in which the
conducted interference in the frequency range is to be reduced in accordance with EMC
regulations. The machine manufacturer must carry out EMC-compliant CE certification for
the product before it is implemented.
General conditions regarding line filters for Smart Line Modules
• In conjunction with the line filters and the associated line reactors, drive line-ups with
• Total cable length: ≤ 350 m
4-14
6SL3000
unit
kW
V
AC
Hz
A
AC
W
kg
Basic Line Modules fulfill the requirements of limit value class A1 to EN55011.
0BE21-
0BE23-
6AA0
6AA0
16
36
3AC 380 -10% to 3AC 480 +10% (-15% < 1 min)
47 to 63 Hz
30
67
70
90
9
16
Equipment Manual Booksize Cold-Plate Power Sections
Manual, (GH4), Edition 06.2005, 6SL3097-2AJ00-0BP2
0BE25-
0BE28-
5AA0
0AA0
55
80
103
150
110
150
19
22
0BE31-
2AA0
120
225
200
32