Figure 7: Front Panel of the Craft Interface
Routing
Engine
LEDs
MASTER
ONLINE
OFFLINE
RE0
OK
FAIL
0
SCB/RE LEDs
and online/offline buttons
NOTE:
At least one SCB must be installed in the services gateway for the craft interface to
obtain power.
SRX5600 Services Gateway Craft Interface Alarm LEDs and Alarm
Cutoff/Lamp Test Button
Two large alarm LEDs are located at the upper right of the craft interface. The circular red LED lights to
indicate a critical condition that can result in a system shutdown. The triangular yellow LED lights to indicate
a less severe condition that requires monitoring or maintenance. Both LEDs can be lit simultaneously. A
condition that causes an LED to light also activates the corresponding alarm relay contact on the craft
interface.
To deactivate the red and yellow alarms, press the button labeled ACO/LT (for "alarm cutoff/lamp test"),
which is located to the right of the alarm LEDs. Deactivating an alarm turns off both LEDs and deactivates
the device attached to the corresponding alarm relay contact on the craft interface.
Table 5 on page 36
describes the alarm LEDs and alarm cutoff button in more detail.
Fan
LEDs
PEM
FAN
RE1
OK
FAIL
OK
FAIL
OK
FAIL
OK
1
0
1
2
IOC and SPC LEDs
and online/offline buttons
Yellow
Red
Alarm
PEM
alarm
alarm
cutoff
LEDs
LED
LED
button
ACO/LT
0
1 2
3
FAIL
OK
FAIL
OK
FAIL
OK
FAIL
3
4
5
Alarm
relay
contacts
YELLOW ALARM RED ALARM
NC
C
NO
NC
C
NO
35