Srx5600 Power System; Srx5600 Services Gateway Power System Overview - Juniper SRX5600 Hardware Manual

Services gateway
Hide thumbs Also See for SRX5600:
Table of Contents

Advertisement

SRX3400 Services Gateway Chassis
SRX5600 Services Gateway Chassis | 29

SRX5600 Power System

IN THIS SECTION

SRX5600 Services Gateway Power System Overview | 47

SRX5600 Services Gateway AC Power Supply | 49
SRX5600 Services Gateway AC Power Supply Specifications | 51
SRX5600 Services Gateway AC Power Supply LEDs | 51
AC Power Cord Specifications for the SRX5600 Services Gateway | 52
AC Power Circuit Breaker Requirements for the SRX5600 Services Gateway | 55
SRX5600 Services Gateway DC Power Supply | 55
SRX5600 Services Gateway DC Power Supply Specifications | 56
SRX5600 Services Gateway DC Power Supply LEDs | 57
DC Power Cable Specifications for the SRX5600 Services Gateway | 58
DC Power Cable Lug Specifications for the SRX5600 Services Gateway | 59
DC Power Circuit Breaker Requirements for the SRX5600 Services Gateway | 59
DC Power Source Cabling for the SRX5600 Services Gateway | 60
SRX5600 Services Gateway Chassis Grounding Point Specifications | 61
SRX5600 Services Gateway Grounding-Cable Lug Specification | 62
SRX5600 Services Gateway Power System Overview
The services gateway uses either AC or DC power supplies. The services gateway is configurable with
two, three, or four AC power supplies or two or four DC power supplies. The power supplies are located
horizontally at the rear of the chassis in slots PEM0 through PEM3 (left to right). The power supplies
connect to the midplane, which distributes the different output voltages produced by the power supplies
to the services gateway components, depending on their voltage requirements. Each power supply is
cooled by its own internal cooling system.