Ordering Examples; Selection And Ordering Data 1Fw6 - Siemens SIMOTICS T-1FW6 Series Configuration Manual

Naturally cooled built-in torgue motors for sinamics s120
Hide thumbs Also See for SIMOTICS T-1FW6 Series:
Table of Contents

Advertisement

Description of the motor
2.5 Selection and ordering data
2.5.1.5

Ordering examples

Example 1:
Stator and rotor pre-assembled with transport locks; cooling jacket; axial cable outlet for
SINAMICS S120 drive system, Motor Modules 18 A / 36 A, permanently connected power
and signal cables with open conductor ends, length: 2 m:
Article number 1FW6063-0KB15-1JC1
Example 2:
Individual component/stator as spare part: Article number 1FW6063-8KB15-1JC1
The following rotor fits this stator.
Individual component/rotor as spare part: Article number 1FW6060-8RA15-0AA0
2.5.2

Selection and ordering data 1FW6

Note
Overview of important motor data
A selection of important motor data and dimensions is provided in this chapter. You can find
all of the data in Chapter "Technical data and characteristics (Page 109)" – and in Chapter
"Installation drawings/dimension sheets (Page 171)".
42
Naturally cooled 1FW6 built-in torque motors
Configuration Manual, 07/2017, 6SN1197-0AE01-0BP3

Advertisement

Table of Contents
loading

Table of Contents